Steam Coming From Your Heat Pump? Here's What's Normal

On a cold, damp North Jersey morning your heat pump may puff out a cloud of steam. It looks alarming, but it's usually the unit doing exactly what it's designed to do.

Illustrated diagram of a heat pump outdoor unit in defrost mode, with labels for steam, a paused fan, a whoosh sound, and ice that stays.

If you have a heat pump, sooner or later you'll look outside on a cold morning and see a cloud of steam rising from the outdoor unit. Before you reach for the phone: in most cases, that's defrost mode, and it's normal.

Why heat pumps defrost

In heating mode, a heat pump pulls heat out of the outdoor air. That makes its outdoor coil colder than the air around it, so on cold, damp days frost builds up on the coil. As Trane explains, the coil can run 10 to 20 degrees colder than the outdoor air, so defrost can happen even in the low 40s, and it's more common in the 20s and 30s.

To clear that frost, the system briefly reverses the flow of refrigerant and warms the outdoor coil. Once the frost melts, it switches back to heating. Lennox says a typical cycle lasts about 5 to 15 minutes, depending on the weather and how much frost there is.

What's normal during defrost

  • Steam. The cloud you see is water vapor from the melting frost, not smoke.
  • The outdoor fan stops. The fan can pause while the coil warms up.
  • A whoosh. You may hear a swooshing sound outside as the refrigerant flow reverses, and the compressor may sound different for a moment.
  • "AUX" on the thermostat. Some systems turn on backup heat during defrost so the house stays comfortable.
  • More cycles on damp days. Cold, wet weather means more frost and more defrosting. Dry, sunny days may need little or none.

When it's not normal

  • Ice that stays. If frost or ice keeps building and covers the unit instead of clearing, have it checked.
  • Constant defrosting. A unit that seems to switch into defrost over and over.
  • Longer and longer cycles. One long cycle on an icy day isn't a problem; repeated long ones are.
  • The house is getting colder. A real drop in comfort along with any of the above.

According to Lennox, causes can include dirty or blocked coils, faulty sensors or controls, or a low refrigerant charge. Those are jobs for a licensed technician.

What you can do

  • Keep it clear. Lennox recommends at least two feet of clearance around the outdoor unit. Brush away snow, leaves and debris so air can reach the coil.
  • Don't chip at the ice. Lennox warns that tools can damage the coil, fins and fan blades. If ice won't clear on its own, call a pro.
  • Check your gutters. Lennox also advises making sure gutters and downspouts don't drain onto or near the unit.
  • Get a yearly tune-up. Clean coils and working sensors help defrost do its job.

Not sure whether what you're seeing is normal? Call us. We're open 24/7 and can take a look.

Heat pump iced over?
Same-day HVAC service across North Jersey, 24/7. $79 diagnostic credited toward the repair. Call (866) 737-2830 or book online.
Book a technician →
Why is my heat pump steaming in winter?
It's usually defrost mode. The unit warms its outdoor coil to melt frost, and the steam is water vapor from that melting frost.
How long does a heat pump defrost cycle last?
Typically a few minutes. Lennox puts a typical cycle at about 5 to 15 minutes, depending on the weather and frost level.
Is it normal for the outdoor fan to stop during defrost?
Yes. The outdoor fan can pause while the coil warms, and you may hear a whoosh as the refrigerant reverses.
When should I call for service?
If ice keeps covering the unit, it defrosts constantly, cycles keep getting longer, or your home is getting colder.